What is the cause of frangible framed filter press plates?
When the sludge is too thick or dry block left, it will cause the supply port plugging, at the time there is no media between the filter only the pressure of the hydraulic system itself, the plate itself can easily be damaged due to long-term damage . Inadequate supply or supply contains unsuitable solid particles, also will cause the plate frame itself too much force to damage. If the outlet is clogged with solids or when the feed valve or outlet valve is closed, the pressure is nowhere to leak, causing damage. When the filter plate is not clean, the media sometimes leaks out. Once it leaks, the edges of the plate frame will be washed out with a small groove to prevent the pressure from rising and the mud cake can not be formed.
The above is framed filter press plate vulnerable reasons, I hope we can help.
A detailed introduction to the belt filter press plate